TY - JOUR
T1 - CT Colonography Data Interpretation
T2 - Effect of Different Section Thicknesses-Preliminary Observations
AU - Lui, Yvonne W.
AU - Macari, Michael
AU - Israel, Gary
AU - Bini, Edmund J.
AU - Wang, Hao
AU - Babb, James
PY - 2003/12
Y1 - 2003/12
N2 - PURPOSE: To evaluate if differences exist in the interpretation of thin- and thick-section reconstructions at computed tomographic (CT) colonography. MATERIALS AND METHODS: Twenty-five patients underwent multi-detector row CT colonography prior to colonoscopy. CT images were reconstructed with two methods: 1.25-mm sections reconstructed every 1 mm (thin) and 5-mm sections reconstructed every 2 mm (thick). Two independent readers interpreted thin sections, then waited a minimum of 15 days before interpreting thick sections. With colonoscopy as the reference standard, comparisons were made between interpretation of thin and thick sections, including sensitivity, specificity, and number of false-positive observations. Interpretation times were recorded, and comparisons were made by using repeated measures analysis of variance. For all tests, P < .05 indicated a statistically significant difference. RESULTS: At colonoscopy, 10 patients had 12 polyps (≤5 mm, n = 7; 6-9 mm, n = 2; ≥10 mm, n = 3). Sensitivity for polyp detection was statistically indistinguishable for thin and thick sections. Reader 1 had three false-positive findings with thin sections and six with thick sections. Reader 2 had six false-positive findings with thin sections and 11 with thick sections. For both readers, the number of false-positive findings was significantly lower for thin sections than for thick sections (P = .035). Specificity was 93.3% with thin sections and 80.0% with thick sections for reader 1 and 80.0% with thin sections and 73.3% with thick sections for reader 2. Mean interpretation time for reader 1 was significantly longer with thin sections (P < .001). Mean interpretation time for reader 2 was 13.0 minutes for both thin and thick sections. CONCLUSION: Specificity improved for both readers with thin sections, with no difference in sensitivity.
AB - PURPOSE: To evaluate if differences exist in the interpretation of thin- and thick-section reconstructions at computed tomographic (CT) colonography. MATERIALS AND METHODS: Twenty-five patients underwent multi-detector row CT colonography prior to colonoscopy. CT images were reconstructed with two methods: 1.25-mm sections reconstructed every 1 mm (thin) and 5-mm sections reconstructed every 2 mm (thick). Two independent readers interpreted thin sections, then waited a minimum of 15 days before interpreting thick sections. With colonoscopy as the reference standard, comparisons were made between interpretation of thin and thick sections, including sensitivity, specificity, and number of false-positive observations. Interpretation times were recorded, and comparisons were made by using repeated measures analysis of variance. For all tests, P < .05 indicated a statistically significant difference. RESULTS: At colonoscopy, 10 patients had 12 polyps (≤5 mm, n = 7; 6-9 mm, n = 2; ≥10 mm, n = 3). Sensitivity for polyp detection was statistically indistinguishable for thin and thick sections. Reader 1 had three false-positive findings with thin sections and six with thick sections. Reader 2 had six false-positive findings with thin sections and 11 with thick sections. For both readers, the number of false-positive findings was significantly lower for thin sections than for thick sections (P = .035). Specificity was 93.3% with thin sections and 80.0% with thick sections for reader 1 and 80.0% with thin sections and 73.3% with thick sections for reader 2. Mean interpretation time for reader 1 was significantly longer with thin sections (P < .001). Mean interpretation time for reader 2 was 13.0 minutes for both thin and thick sections. CONCLUSION: Specificity improved for both readers with thin sections, with no difference in sensitivity.
KW - Colon neoplasms
KW - Colon neoplasms, CT
KW - Computed tomography (CT), multidetector row
KW - Computed tomography (CT), thin-section
UR - http://www.scopus.com/inward/record.url?scp=0345015530&partnerID=8YFLogxK
U2 - 10.1148/radiol.2293021404
DO - 10.1148/radiol.2293021404
M3 - Article
C2 - 14593196
AN - SCOPUS:0345015530
SN - 0033-8419
VL - 229
SP - 791
EP - 797
JO - Radiology
JF - Radiology
IS - 3
ER -