TY - JOUR
T1 - Cryoballoon ablation of pulmonary veins for persistent atrial fibrillation
T2 - Results from the multicenter STOP Persistent AF trial
AU - STOP Persistent AF Investigators
AU - Su, Wilber W.
AU - Reddy, Vivek Y.
AU - Bhasin, Kabir
AU - Champagne, Jean
AU - Sangrigoli, Robert M.
AU - Braegelmann, Kendra M.
AU - Kueffer, Fred J.
AU - Novak, Paul
AU - Gupta, Sanjaya K.
AU - Yamane, Teiichi
AU - Calkins, Hugh
N1 - Publisher Copyright:
© 2020 Heart Rhythm Society
PY - 2020/11
Y1 - 2020/11
N2 - Background: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation to treat patients with symptomatic drug-refractory atrial fibrillation (AF). Objective: The purpose of this study was to assess the safety and efficacy of PVI using the cryoballoon catheter to treat patients with persistent AF. Methods: STOP Persistent AF (ClinicalTrials.gov Identifier: NCT03012841) was a prospective, multicenter, single-arm, Food and Drug Administration–regulated trial designed to evaluate the safety and efficacy of PVI-only cryoballoon ablation for drug-refractory persistent AF (continuous episodes <6 months). The primary efficacy endpoint was 12-month freedom from ≥30 seconds of AF, atrial flutter (AFL), or atrial tachycardia (AT) after a 90-day blanking period. The prespecified performance goals were set at >40% and <13% for the primary efficacy and safety endpoints, respectively. Secondary endpoints assessed quality of life using the AFEQT (Atrial Fibrillation Effect on Quality of Life) and SF (Short Form)-12 questionnaires. Results: Of 186 total enrollments, 165 subjects (70% male; age 65 ± 9 years; left atrial diameter 4.2 ± 0.6 cm; body mass index 31 ± 6) were treated at 25 sites in the United States, Canada, and Japan. Total procedural, left atrial dwell, and fluoroscopy times were 121 ± 46 minutes, 102 ± 41 minutes, and 19 ± 16 minutes, respectively. At 12 months, the primary efficacy endpoint was 54.8% (95% confidence [CI] 46.7%–62.1%) freedom from AF, AFL, or AT. There was 1 primary safety event, translating to a rate of 0.6% (95% CI 0.1%–4.4%). AFEQT and SF-12 assessments demonstrated significant improvements from baseline to 12 months postablation (P <.001). Conclusion: The STOP Persistent AF trial demonstrated cryoballoon ablation to be safe and effective in treating patients with drug-refractory persistent AF characterized by continuous AF episodes <6 months.
AB - Background: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation to treat patients with symptomatic drug-refractory atrial fibrillation (AF). Objective: The purpose of this study was to assess the safety and efficacy of PVI using the cryoballoon catheter to treat patients with persistent AF. Methods: STOP Persistent AF (ClinicalTrials.gov Identifier: NCT03012841) was a prospective, multicenter, single-arm, Food and Drug Administration–regulated trial designed to evaluate the safety and efficacy of PVI-only cryoballoon ablation for drug-refractory persistent AF (continuous episodes <6 months). The primary efficacy endpoint was 12-month freedom from ≥30 seconds of AF, atrial flutter (AFL), or atrial tachycardia (AT) after a 90-day blanking period. The prespecified performance goals were set at >40% and <13% for the primary efficacy and safety endpoints, respectively. Secondary endpoints assessed quality of life using the AFEQT (Atrial Fibrillation Effect on Quality of Life) and SF (Short Form)-12 questionnaires. Results: Of 186 total enrollments, 165 subjects (70% male; age 65 ± 9 years; left atrial diameter 4.2 ± 0.6 cm; body mass index 31 ± 6) were treated at 25 sites in the United States, Canada, and Japan. Total procedural, left atrial dwell, and fluoroscopy times were 121 ± 46 minutes, 102 ± 41 minutes, and 19 ± 16 minutes, respectively. At 12 months, the primary efficacy endpoint was 54.8% (95% confidence [CI] 46.7%–62.1%) freedom from AF, AFL, or AT. There was 1 primary safety event, translating to a rate of 0.6% (95% CI 0.1%–4.4%). AFEQT and SF-12 assessments demonstrated significant improvements from baseline to 12 months postablation (P <.001). Conclusion: The STOP Persistent AF trial demonstrated cryoballoon ablation to be safe and effective in treating patients with drug-refractory persistent AF characterized by continuous AF episodes <6 months.
KW - Cryoballoon ablation
KW - Persistent atrial fibrillation
KW - Pulmonary vein isolation
KW - Quality of life
KW - Repeat ablation
UR - http://www.scopus.com/inward/record.url?scp=85089550622&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2020.06.020
DO - 10.1016/j.hrthm.2020.06.020
M3 - Article
C2 - 32590151
AN - SCOPUS:85089550622
SN - 1547-5271
VL - 17
SP - 1841
EP - 1847
JO - Heart Rhythm
JF - Heart Rhythm
IS - 11
ER -