TY - JOUR
T1 - Considerations for quality assurance of multiplex malaria antigen detection assays with large sample sets
AU - Alvarado, Rachel
AU - van den Hoogen, Lotus L.
AU - Iriemenam, Nnaemeka C.
AU - Akinmulero, Oluwaseun O.
AU - Thomas, Andrew N.
AU - Tamunonengiyeofori, Israel
AU - Erasogie, Evbuomwan
AU - Chimaoge, Achugbu C.
AU - Dawurung, Ayuba B.
AU - Esiekpe, Mudiaga K.
AU - Okoli, Mary U.
AU - Mba, Nwando
AU - Ogunniyi, Abiodun
AU - Abimiku, Alash’le
AU - Maire, Mark
AU - Bassey, Orji O.
AU - Okoye, McPaul P.
AU - Swaminathan, Mahesh
AU - Greby, Stacie M.
AU - Ndodo, Nnaemeka
AU - Ihekweazu, Chikwe
AU - Abubakar, Ado
AU - Steinhardt, Laura
AU - Rogier, Eric
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2021/12
Y1 - 2021/12
N2 - Multiplex assays for malaria antigen detection can gather data from large sample sets, but considerations for the consistency and quality assurance (QA) of mass testing lack evaluation. We present a QA framework for a study occurring November 2019 to March 2020 involving 504 assay plates detecting four Plasmodium antigens: pan-Plasmodium aldolase and lactate dehydrogenase (LDH), histidine-rich protein 2 (HRP2), P. vivax LDH (PvLDH). Controls on each plate included buffer blank, antigen negative blood, and 4-point positive dilution curve. The blank and negative blood provided consistently low signal for all targets except for pAldolase, which showed variability. Positive curve signals decreased throughout the 5-month study duration but retained a coefficient of variation (CV) of < 5%, with the exception of HRP2 in month 5 (CV of 11%). Regression fittings for inter-plate control signals provided mean and standard deviations (SDs), and of 504 assay plates, 6 (1.2%) violated the acceptable deviation limits and were repeated. For the 40,272 human blood samples assayed in this study, of 161,088 potential data points (each sample × 4 antigens), 160,641 (99.7%) successfully passed quality checks. The QA framework presented here can be utilized to ensure quality of laboratory antigen detection for large sample sets.
AB - Multiplex assays for malaria antigen detection can gather data from large sample sets, but considerations for the consistency and quality assurance (QA) of mass testing lack evaluation. We present a QA framework for a study occurring November 2019 to March 2020 involving 504 assay plates detecting four Plasmodium antigens: pan-Plasmodium aldolase and lactate dehydrogenase (LDH), histidine-rich protein 2 (HRP2), P. vivax LDH (PvLDH). Controls on each plate included buffer blank, antigen negative blood, and 4-point positive dilution curve. The blank and negative blood provided consistently low signal for all targets except for pAldolase, which showed variability. Positive curve signals decreased throughout the 5-month study duration but retained a coefficient of variation (CV) of < 5%, with the exception of HRP2 in month 5 (CV of 11%). Regression fittings for inter-plate control signals provided mean and standard deviations (SDs), and of 504 assay plates, 6 (1.2%) violated the acceptable deviation limits and were repeated. For the 40,272 human blood samples assayed in this study, of 161,088 potential data points (each sample × 4 antigens), 160,641 (99.7%) successfully passed quality checks. The QA framework presented here can be utilized to ensure quality of laboratory antigen detection for large sample sets.
UR - https://www.scopus.com/pages/publications/85108621490
U2 - 10.1038/s41598-021-92723-w
DO - 10.1038/s41598-021-92723-w
M3 - Article
C2 - 34168264
AN - SCOPUS:85108621490
SN - 2045-2322
VL - 11
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 13248
ER -