TY - JOUR
T1 - Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions
AU - Robson, Philip M.
AU - Grant, Aaron K.
AU - Madhuranthakam, Ananth J.
AU - Lattanzi, Riccardo
AU - Sodickson, Daniel K.
AU - McKenzie, Charles A.
PY - 2008/10
Y1 - 2008/10
N2 - Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques.
AB - Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques.
KW - Image noise
KW - Image reconstruction
KW - Parallel imaging
KW - Signal-to-noise ratio
KW - g-factor
UR - http://www.scopus.com/inward/record.url?scp=53549094426&partnerID=8YFLogxK
U2 - 10.1002/mrm.21728
DO - 10.1002/mrm.21728
M3 - Article
C2 - 18816810
AN - SCOPUS:53549094426
SN - 0740-3194
VL - 60
SP - 895
EP - 907
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
IS - 4
ER -