Comparison of magnetic resonance imaging mismatch criteria to select patients for endovascular stroke therapy

  • Nishant K. Mishra
  • , Gregory W. Albers
  • , Søren Christensen
  • , Michael Marks
  • , Scott Hamilton
  • , Matus Straka
  • , John T.P. Liggins
  • , Stephanie Kemp
  • , Michael Mlynash
  • , Roland Bammer
  • , Maarten G. Lansberg

Research output: Contribution to journal › Article › peer-review

21 Scopus citations

Abstract

BACKGROUND AND PURPOSE-: The Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution 2 (DEFUSE 2) study has shown that clinical response to endovascular reperfusion differs between patients with and without perfusion-diffusion (perfusion-weighted imaging-diffusion-weighted imaging, PWI-DWI) mismatch: patients with mismatch have a favorable clinical response to reperfusion, whereas patients without mismatch do not. This study examined whether alternative mismatch criteria can also differentiate patients according to their response to reperfusion. METHODS-: Patients from the DEFUSE 2 study were categorized according to vessel occlusion on magnetic resonance angiography (MRA) and DWI lesion volume criteria (MRA-DWI mismatch) and symptom severity and DWI criteria (clinical-DWI mismatch). Favorable clinical response was defined as an improvement of ?8 points on the National Institutes of Health Stroke Scale (NIHSS) by day 30 or an NIHSS score of ≤1 at day 30. We assessed, for each set of criteria, whether the association between reperfusion and favorable clinical response differed according to mismatch status. RESULTS-: A differential response to reperfusion was observed between patients with and without MRA-DWI mismatch defined as an internal carotid artery or M1 occlusion and a DWI lesion <50 mL. Reperfusion was associated with good functional outcome in patients who met these MRA-DWI mismatch criteria (odds ratio [OR], 8.5; 95% confidence interval [CI], 2.3-31.3), whereas no association was observed in patients who did not meet these criteria (OR, 0.5; 95% CI, 0.08-3.1; P for difference between the odds, 0.01). No differential response to reperfusion was observed with other variations of the MRA-DWI or clinical-DWI mismatch criteria. CONCLUSIONS-: The MRA-DWI mismatch is a promising alternative to DEFUSE 2's PWI-DWI mismatch for patient selection in endovascular stroke trials.

Original languageEnglish
Pages (from-to)1369-1374
Number of pages6
JournalStroke
Volume45
Issue number5
DOIs
StatePublished - May 2014
Externally publishedYes

Keywords

  • Reperfusion
  • Stroke

Fingerprint

Dive into the research topics of 'Comparison of magnetic resonance imaging mismatch criteria to select patients for endovascular stroke therapy'. Together they form a unique fingerprint.

Cite this