Skip to main navigation Skip to search Skip to main content

Comparison of far-field and peak frequency electrogram characteristics at the earliest activation sites during idiopathic ventricular arrhythmias: A novel index to predict ablation success

  • Takuro Nishimura
  • , Natsuki Kanazawa
  • , Yasutoshi Nagata
  • , Shinsuke Iwai
  • , Yukio Sekiguchi
  • , Kenji Okubo
  • , Yoshihide Takahashi
  • , Yasuteru Yamauchi
  • , Naoyuki Miwa
  • , Akira Mizukami
  • , Miho Negishi
  • , Masaki Honda
  • , Ryo Tateishi
  • , Iwanari Kawamura
  • , Kentaro Goto
  • , Kazuya Yamao
  • , Susumu Tao
  • , Masateru Takigawa
  • , Shinsuke Miyazaki
  • , Tetsuo Sasano

Research output: Contribution to journal › Article › peer-review

3 Scopus citations

Abstract

Background Evaluating the peak frequency electrograms (EGMs) has the potential to differentiate near-field from far-field components. Objective This study examined how peak frequency analyses of EGMs preceding idiopathic ventricular arrhythmias (VAs) affect catheter ablation outcomes. Methods A retrospective analysis was conducted on 111 VAs from 104 patients. EGMs at the earliest activation site, detected using high-density activation maps, were analyzed to assess the association with a successful elimination after a single radiofrequency delivery. Results In outflow tract VAs (n = 77), the first deflection timing was similar for VAs with and without a successful elimination. The peak frequency timing was earlier (right ventricular outflow tract -21 ms [-32 to -16 ms] vs -11 ms [-20 to 0 ms], P =.002; left ventricular outflow tract -26 ms [-33 to -4 ms] vs 0 ms [-6 to 10 ms], P =.005) and the difference between the first deflection and peak frequency timing (delta F-P) shorter (right ventricular outflow tract 7 ms [5-13 ms] vs 17 ms [11-24 ms], P <.001; left ventricular outflow tract 10 ms [6-19 ms] vs 22 ms [20-27 ms], P =.001) for VAs with a successful elimination than for those without. The delta F-P correlated with the time to elimination of outflow tract VAs (P =.01; r = 0.45). None of the outflow tract VAs with a delta F-P of >22 ms achieved a successful elimination. For non-outflow tract VAs (n = 34), no parameters were associated with a successful elimination. Conclusion The first component of the EGM at the earliest activation site may reflect a far-field recording from the site of origin of idiopathic VAs. A novel delta F-P EGM index may predict quick, successful endocardial ablation of outflow tract VAs.

Original languageEnglish
JournalHeart Rhythm
Volume23
Issue number3
DOIs
StatePublished - 1 Mar 2026
Externally publishedYes

Keywords

  • Catheter ablation
  • Electroanatomic mapping
  • Peak frequency
  • Prepotentials
  • Ventricular arrhythmia