T1 - Comparison of digestion procedures and methods for quantification of trace lead in breast milk by isotope dilution inductively coupled plasma mass spectrometry
AU - Amarasiriwardena, Chitra J.
AU - Jayawardene, Innocent
AU - Lupoli, Nicola
AU - Barnes, Ramon M.
AU - Hernandez-Avila, Mauricio
AU - Hu, Howard
AU - Ettinger, Adrienne S.
PY - 2013/4/7
Y1 - 2013/4/7
N2 - Measurement of lead in breast milk is an important public health consideration and can be technically quite challenging. The reliable and accurate determination of trace lead in human breast milk is difficult for several reasons including: potential for contamination during sample collection, storage, and analysis; complexities related to the high fat content of human milk; and poor analytic sensitivity at low concentrations. Breast milk lead levels from previous published studies should therefore be reviewed with caution. Due to the difficulty in identifying a method that would successfully digest samples with 100% efficiency, we evaluated three different digestion procedures including: (1) dry ashing in a muffle furnace, (2) microwave oven digestion, and (3) digestion in high pressure asher. High temperature, high pressure asher digestion was selected as the procedure of choice for the breast milk samples. Trace lead analysis was performed using isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS). Measured lead concentrations in breast milk samples (n = 200) from Mexico ranged from 0.2 to 6.7 ng ml-1. The precision for these measurements ranged from 0.27-7.8% RSD. Use of strict contamination control techniques and of a very powerful digestion procedure, along with an ID-ICP-MS method for lead determination, enables us to measure trace lead levels as low as 0.2 ng ml -1 in milk (instrument detection limit = 0.01 ng ml-1).
AB - Measurement of lead in breast milk is an important public health consideration and can be technically quite challenging. The reliable and accurate determination of trace lead in human breast milk is difficult for several reasons including: potential for contamination during sample collection, storage, and analysis; complexities related to the high fat content of human milk; and poor analytic sensitivity at low concentrations. Breast milk lead levels from previous published studies should therefore be reviewed with caution. Due to the difficulty in identifying a method that would successfully digest samples with 100% efficiency, we evaluated three different digestion procedures including: (1) dry ashing in a muffle furnace, (2) microwave oven digestion, and (3) digestion in high pressure asher. High temperature, high pressure asher digestion was selected as the procedure of choice for the breast milk samples. Trace lead analysis was performed using isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS). Measured lead concentrations in breast milk samples (n = 200) from Mexico ranged from 0.2 to 6.7 ng ml-1. The precision for these measurements ranged from 0.27-7.8% RSD. Use of strict contamination control techniques and of a very powerful digestion procedure, along with an ID-ICP-MS method for lead determination, enables us to measure trace lead levels as low as 0.2 ng ml -1 in milk (instrument detection limit = 0.01 ng ml-1).
UR - http://www.scopus.com/inward/record.url?scp=84879536041&partnerID=8YFLogxK
U2 - 10.1039/c3ay26321e
DO - 10.1039/c3ay26321e
M3 - Article
AN - SCOPUS:84879536041
SN - 1759-9660
VL - 5
SP - 1676
EP - 1681
JO - Analytical Methods
JF - Analytical Methods
IS - 7
ER -