TY - JOUR
T1 - Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
AU - Egami, Yasuyuki
AU - Nishino, Masami
AU - Nohara, Hiroaki
AU - Kawanami, Shodai
AU - Sugae, Hiroki
AU - Ukita, Kohei
AU - Kawamura, Akito
AU - Nakamura, Hitoshi
AU - Yasumoto, Koji
AU - Tsuda, Masaki
AU - Okamoto, Naotaka
AU - Matsunaga-Lee, Yasuharu
AU - Yano, Masamichi
AU - Tanouchi, Jun
N1 - Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2023/10
Y1 - 2023/10
N2 - Background: An ablation index (AI)-guided pulmonary vein isolation (PVI) or 2nd generation cryoballoon (CB)-PVI has been shown to reduce the atrial fibrillation (AF) burden by 99% despite the absence of ablation of non-pulmonary vein (PV) triggers in patients with paroxysmal AF. The purpose of this study was to investigate the effects of PVI alone strategy using 2nd generation CB compared with AI-guided PVI with an additional induction test and subsequent AF trigger ablation. Methods and results: We investigated 223 patients with symptomatic paroxysmal AF who underwent an initial PVI between August 2018 and August 2020. The study patients were divided into 2 groups: CB-PVI without an induction test (CB-PVI alone group, n = 82) and AI-guided PVI with an induction test and subsequent additional ablation of non-PV triggers (AI-PVI plus group, n = 141). In the AI-PVI plus group, a total of 62 non-PV triggers were induced in 38 patients, and non-PV triggers in 22 patients were completely ablated. The procedure time and left atrium dwell time were significantly shorter in the CB-PVI alone group than AI-PVI plus group. There were no significant differences in the incidence of procedural complications between the 2 groups (P = 0.650). The AF free survival rate in the CB-PVI alone group and AI-PVI plus group was 80% vs. 80% at 24 months (P = 0.969). Conclusions: An PVI alone strategy using advanced generation CB did not differ in the clinical outcomes compared with an AI-guided PVI strategy with an induction test and subsequent ablation of non-PV triggers in the patients with paroxysmal AF.
AB - Background: An ablation index (AI)-guided pulmonary vein isolation (PVI) or 2nd generation cryoballoon (CB)-PVI has been shown to reduce the atrial fibrillation (AF) burden by 99% despite the absence of ablation of non-pulmonary vein (PV) triggers in patients with paroxysmal AF. The purpose of this study was to investigate the effects of PVI alone strategy using 2nd generation CB compared with AI-guided PVI with an additional induction test and subsequent AF trigger ablation. Methods and results: We investigated 223 patients with symptomatic paroxysmal AF who underwent an initial PVI between August 2018 and August 2020. The study patients were divided into 2 groups: CB-PVI without an induction test (CB-PVI alone group, n = 82) and AI-guided PVI with an induction test and subsequent additional ablation of non-PV triggers (AI-PVI plus group, n = 141). In the AI-PVI plus group, a total of 62 non-PV triggers were induced in 38 patients, and non-PV triggers in 22 patients were completely ablated. The procedure time and left atrium dwell time were significantly shorter in the CB-PVI alone group than AI-PVI plus group. There were no significant differences in the incidence of procedural complications between the 2 groups (P = 0.650). The AF free survival rate in the CB-PVI alone group and AI-PVI plus group was 80% vs. 80% at 24 months (P = 0.969). Conclusions: An PVI alone strategy using advanced generation CB did not differ in the clinical outcomes compared with an AI-guided PVI strategy with an induction test and subsequent ablation of non-PV triggers in the patients with paroxysmal AF.
KW - Atrial fibrillation
KW - Cryoballoon ablation
KW - Induction test
KW - Non-pulmonary vein trigger
KW - Radiofrequency ablation
UR - https://www.scopus.com/pages/publications/85144946263
U2 - 10.1007/s10840-022-01459-8
DO - 10.1007/s10840-022-01459-8
M3 - Article
C2 - 36575227
AN - SCOPUS:85144946263
SN - 1383-875X
VL - 66
SP - 1571
EP - 1580
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 7
ER -