TY - JOUR
T1 - Co-occurrence profiles of trace elements in potable water systems
T2 - a case study
AU - Andra, Syam S.
AU - Makris, Konstantinos C.
AU - Charisiadis, Pantelis
AU - Costa, Costas N.
N1 - Publisher Copyright:
© 2014, Springer International Publishing Switzerland.
PY - 2014/10/3
Y1 - 2014/10/3
N2 - Potable water samples (N = 74) from 19 zip code locations in a region of Greece were profiled for 13 trace elements composition using inductively coupled plasma mass spectrometry. The primary objective was to monitor the drinking water quality, while the primary focus was to find novel associations in trace elements occurrence that may further shed light on common links in their occurrence and fate in the pipe scales and corrosion products observed in urban drinking water distribution systems. Except for arsenic at two locations and in six samples, rest of the analyzed elements was below maximum contaminant levels, for which regulatory values are available. Further, we attempted to hierarchically cluster trace elements based on their covariances resulting in two groups; one with arsenic, antimony, zinc, cadmium, and copper and the second with the rest of the elements. The grouping trends were partially explained by elements’ similar chemical activities in water, underscoring their potential for co-accumulation and co-mobilization phenomena from pipe scales into finished water. Profiling patterns of trace elements in finished water could be indicative of their load on pipe scales and corrosion products, with a corresponding risk of episodic contaminant release. Speculation was made on the role of disinfectants and disinfection byproducts in mobilizing chemically similar trace elements of human health interest from pipe scales to tap water. It is warranted that further studies may eventually prove useful to water regulators from incorporating the acquired knowledge in the drinking water safety plans.
AB - Potable water samples (N = 74) from 19 zip code locations in a region of Greece were profiled for 13 trace elements composition using inductively coupled plasma mass spectrometry. The primary objective was to monitor the drinking water quality, while the primary focus was to find novel associations in trace elements occurrence that may further shed light on common links in their occurrence and fate in the pipe scales and corrosion products observed in urban drinking water distribution systems. Except for arsenic at two locations and in six samples, rest of the analyzed elements was below maximum contaminant levels, for which regulatory values are available. Further, we attempted to hierarchically cluster trace elements based on their covariances resulting in two groups; one with arsenic, antimony, zinc, cadmium, and copper and the second with the rest of the elements. The grouping trends were partially explained by elements’ similar chemical activities in water, underscoring their potential for co-accumulation and co-mobilization phenomena from pipe scales into finished water. Profiling patterns of trace elements in finished water could be indicative of their load on pipe scales and corrosion products, with a corresponding risk of episodic contaminant release. Speculation was made on the role of disinfectants and disinfection byproducts in mobilizing chemically similar trace elements of human health interest from pipe scales to tap water. It is warranted that further studies may eventually prove useful to water regulators from incorporating the acquired knowledge in the drinking water safety plans.
KW - Chemical grouping
KW - Co-occurrence
KW - Trace elements’ mixtures
KW - Urban drinking-water distribution systems
KW - Water and Health
KW - Water quality indicators
UR - http://www.scopus.com/inward/record.url?scp=84909987184&partnerID=8YFLogxK
U2 - 10.1007/s10661-014-3928-x
DO - 10.1007/s10661-014-3928-x
M3 - Article
C2 - 25037966
AN - SCOPUS:84909987184
SN - 0167-6369
VL - 186
SP - 7307
EP - 7320
JO - Environmental Monitoring and Assessment
JF - Environmental Monitoring and Assessment
IS - 11
ER -