Skip to main navigation Skip to search Skip to main content

Clinical utility of a patient-specific algorithm for simulating intracerebral drug infusions

  • John H. Sampson
  • , Raghu Raghavan
  • , Martin L. Brady
  • , James M. Provenzale
  • , James E. Herndon
  • , David Croteau
  • , Allan H. Friedman
  • , David A. Reardon
  • , R. Edward Coleman
  • , Terence Wong
  • , Darell D. Bigner
  • , Ira Pastan
  • , María Inmaculada Rodríguez-Ponce
  • , Philipp Tanner
  • , Raj Puri
  • , Christoph Pedain

Research output: Contribution to journalArticlepeer-review

112 Scopus citations

Abstract

Convection-enhanced delivery (CED) is a novel drug delivery technique that uses positive infusion pressure to deliver therapeutic agents directly into the interstitial spaces of the brain. Despite the promise of CED, clinical trials have demonstrated that target-tissue anatomy and patient-specific physiology play a major role in drug distribution using this technique. In this study, we retrospectively tested the ability of a software algorithm using MR diffusion tensor imaging to predict patient-specific drug distributions by CED. A tumor-targeted cytotoxin, cintredekin besudotox (interleukin 13-PE38QQR), was coinfused with iodine 123-labeled human serum albumin (123I-HSA), in patients with recurrent malignant gliomas. The spatial distribution of 123I-HSA was then compared to a drug distribution simulation provided by the software algorithm. The algorithm had a high sensitivity (71.4%) and specificity (100%) for identifying the high proportion (7 of 14) of catheter trajectories that failed to deliver drug into the desired anatomical region (p = 0.021). This usually occurred when catheter trajectories crossed deep sulci, resulting in leak of the infusate into the subarachnoid cerebrospinal fluid space. The mean concordance of the volume of distribution at the 50% isodose level between the actual 123I-HSA distribution and simulation was 65.75% (95% confidence interval [CI], 52.0%-79.5%), and the mean maximal inplane deviation was less than 8.5 mm (95% CI, 4.0-13.0 mm). The use of this simulation algorithm was considered clinically useful in 84.6% of catheters. Routine use of this algorithm, and its further developments, should improve prospective selection of catheter trajectories, and thereby improve the efficacy of drugs delivered by this promising technique.

Original languageEnglish
Pages (from-to)343-353
Number of pages11
JournalNeuro-Oncology
Volume9
Issue number3
DOIs
StatePublished - Jul 2007
Externally publishedYes

Keywords

  • Brain neoplasms
  • Computer simulation
  • Convection
  • Drug delivery systems
  • Single-photon emission computed tomography

Fingerprint

Dive into the research topics of 'Clinical utility of a patient-specific algorithm for simulating intracerebral drug infusions'. Together they form a unique fingerprint.

Cite this