Skip to main navigation Skip to search Skip to main content

Clinical practice of indocyanine green fluorescence imaging in robotic liver surgery – a global expert survey

  • Robotic Liver Surgery Expert Group

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Indocyanine green (ICG) fluorescence imaging is increasingly incorporated into robotic liver resections (RLR), yet clinical practice regarding timing, dosage, and staining techniques is divergent. This international expert survey aimed to characterize current practices for ICG in RLR. Methods: Experts in RLR were invited to participate based on surgical volume (experience of ≥ 50 RLR and ≥ 30 annual RLR). A 74-item questionnaire was developed following a literature search and reviewed by a steering committee. The survey addressed indications, timing, dosage, imaging technology, benefits, limitations, training, and future directions of ICG use. Responses collected between September and October 2025 were analyzed. Results: Seventy experts from 19 countries completed the survey, corresponding to an 88% response rate. Centers performed a median of 180 annual liver resections, including 55 RLR. Most experts used ICG (96%) during RLR. Anatomical demarcation (91%), tumor localization (60%), and biliary anatomy assessment (60%) were the most frequent indications. 60% of experts use preoperative ICG, while intraoperative ICG is mainly administered for demarcation (67%) and biliary tract visualization (40%). Considerable heterogeneity exists in dosage, timing, and staining techniques, particularly in cirrhotic livers and for tumor localization. 53% of the experts had standard operating procedures, whereas 64% expressed the need for a higher degree of standardization. Reported benefits of ICG use included improved anatomical orientation, margin assessment, lesion detection, and support during complex resections. Perceived limitations included background fluorescence, tissue penetration and variable staining in diseased parenchyma. 80% anticipated improved outcomes with combined ICG and three-dimensional image-guidance. Conclusion: ICG fluorescence is widely used in RLR and is an important cornerstone for precision-guided robotic liver surgery. Standardized clinical practice guidelines, structured training, and technological improvements in imaging and navigation systems are claimed to optimize its clinical use.

Original languageEnglish
Pages (from-to)3389-3402
Number of pages14
JournalSurgical Endoscopy
Volume40
Issue number4
DOIs
StatePublished - Apr 2026

Keywords

  • Firefly
  • Indocyanine green
  • Liver resection
  • Robotic liver surgery

Fingerprint

Dive into the research topics of 'Clinical practice of indocyanine green fluorescence imaging in robotic liver surgery – a global expert survey'. Together they form a unique fingerprint.

Cite this