TY - JOUR
T1 - Chorionic villus sampling before multifetal pregnancy reduction
AU - Eddleman, Keith A.
AU - Stone, Joanne L.
AU - Lynch, Lauren
AU - Berkowitz, Richard L.
PY - 2000
Y1 - 2000
N2 - OBJECTIVE: This study was undertaken to determine the technical feasibility and accuracy of chorionic villus sampling before multifetal pregnancy reduction and to determine whether sampling increases the pregnancy loss rate after the reduction procedure. STUDY DESIGN: Between January 22, 1986, and January 20, 2000, a total of 1183 patients underwent first-trimester multifetal pregnancy reduction at Mount Sinai Medical Center. Chorionic villus sampling was attempted in 86 patients before the reduction procedure. Information on the technical success and accuracy of chorionic villus sampling, as well as pregnancy outcome, was collected on all patients. Pregnancy loss rates before 24 weeks' gestation in patients undergoing chorionic villus sampling before multifetal pregnancy reduction were compared with rates in patients not undergoing sampling. RESULTS: Chorionic villus sampling was successfully completed in 85 (98.8%) of 86 patients in whom sampiing was attempted. Of 166 fetuses, 165 (99.4%) were successfully sampled. Of 165 fetuses, 3 (1.8%) had karyotypic abnormalities. Sampling errors were probably made in 2 (1.2%) of 165 fetuses. Of the 73 patients who have been delivered or are beyond 24 weeks' gestation, only 1 patient (1.4%) had a pregnancy loss after the multifetal pregnancy reduction. CONCLUSIONS: Chorionic villus sampling before multifetal pregnancy reduction is technically feasible and accurate, with an acceptably low sampling error rate. Chorionic villus sampling before multifetal pregnancy reduction appears to be safe and does not increase the risk of loss after the reduction procedure.
AB - OBJECTIVE: This study was undertaken to determine the technical feasibility and accuracy of chorionic villus sampling before multifetal pregnancy reduction and to determine whether sampling increases the pregnancy loss rate after the reduction procedure. STUDY DESIGN: Between January 22, 1986, and January 20, 2000, a total of 1183 patients underwent first-trimester multifetal pregnancy reduction at Mount Sinai Medical Center. Chorionic villus sampling was attempted in 86 patients before the reduction procedure. Information on the technical success and accuracy of chorionic villus sampling, as well as pregnancy outcome, was collected on all patients. Pregnancy loss rates before 24 weeks' gestation in patients undergoing chorionic villus sampling before multifetal pregnancy reduction were compared with rates in patients not undergoing sampling. RESULTS: Chorionic villus sampling was successfully completed in 85 (98.8%) of 86 patients in whom sampiing was attempted. Of 166 fetuses, 165 (99.4%) were successfully sampled. Of 165 fetuses, 3 (1.8%) had karyotypic abnormalities. Sampling errors were probably made in 2 (1.2%) of 165 fetuses. Of the 73 patients who have been delivered or are beyond 24 weeks' gestation, only 1 patient (1.4%) had a pregnancy loss after the multifetal pregnancy reduction. CONCLUSIONS: Chorionic villus sampling before multifetal pregnancy reduction is technically feasible and accurate, with an acceptably low sampling error rate. Chorionic villus sampling before multifetal pregnancy reduction appears to be safe and does not increase the risk of loss after the reduction procedure.
KW - Chorionic villus sampling
KW - Multifetal pregnancy reduction
KW - Prenatal diagnosis
UR - http://www.scopus.com/inward/record.url?scp=0033666224&partnerID=8YFLogxK
U2 - 10.1067/mob.2000.108868
DO - 10.1067/mob.2000.108868
M3 - Article
AN - SCOPUS:0033666224
SN - 0002-9378
VL - 183
SP - 1078
EP - 1081
JO - American Journal of Obstetrics and Gynecology
JF - American Journal of Obstetrics and Gynecology
IS - 5
ER -