TY - JOUR
T1 - Characterization of newly detected costal pleura-attached noncalcified nodules at annual low-dose ct screenings
AU - Zhu, Yeqing
AU - Yip, Rowena
AU - You, Nan
AU - Cai, Qiang
AU - Henschke, Claudia I.
AU - Yankelevitz, David F.
N1 - Publisher Copyright:
© 2021 Radiological Society of North America Inc.. All rights reserved.
PY - 2021/12
Y1 - 2021/12
N2 - Background: Solid costal pleura-attached noncalcified nodules (CP-NCNs) less than 10.0 mm with lentiform, oval, or semicircular (LOS) or triangular shapes and smooth margins on baseline low-dose CT scans from the Mount Sinai Early Lung and Cardiac Action Program (MS-ELCAP) were reviewed, and it was determined that they can be followed up at the first annual screening rather than having a shorter-term work-up. Purpose: To determine whether the same criteria could be used for solid CP-NCNs newly identified at annual screening examinations. Materials and Methods: With use of the same MS-ELCAP database, all new solid CP-NCNs measuring 30.0 mm or less were identified at 4425 annual screening examinations between 2010 and 2019. In addition, to ensure that no malignant CP-NCNs met the criteria, all solid malignant CP-NCNs of 30.0 mm or less in the International Early Lung Cancer Action Program, or I-ELCAP, database of 111 102 annual screening examinations from the 76 participating institutions between 1992 and 2019 were identified; Mount Sinai is one of these institutions. All identified solid CP-NCNs were reviewed-with the radiologists blinded to diagnosis- for shape (triangular, LOS, polygonal, round, or irregular), margin (smooth or nonsmooth), pleural attachment (broad or narrow), and the presence of emphysema and/or fibrosis within 10.0 mm of each CP-NCN. Intra- and interreader readings were performed, and agreements were determined by using the B-statistic. Results: Of the 76 new solid CP-NCNs, 21 were lung cancers. Benign CP-NCNs were smaller than malignant ones (median diameter, 4.2 mm vs 11 mm; P <.001), had a different shape distributions, more frequently had smooth margins (67% vs 14%; P <.001), and less frequently had emphysema (38% vs 81%; P = .003) or fibrosis (3.6% vs 19%; P = .045) within a 10.0 mm radius. All 22 solid CP-NCNs less than 10.0 mm in average diameter with triangular or LOS shapes and smooth margins were benign, and none of the 21 solid malignant CP-NCNs had these characteristics. Intra- and interobserver agreement for triangular or LOSshaped CP-NCNs with smooth margins was almost perfect (0.77 and 0.69, respectively). Conclusion: The same follow-up recommendation developed for baseline costal pleura-attached noncalcified nodules (CP-NCNs) can be used for CP-NCNs newly identified at annual screening rounds.
AB - Background: Solid costal pleura-attached noncalcified nodules (CP-NCNs) less than 10.0 mm with lentiform, oval, or semicircular (LOS) or triangular shapes and smooth margins on baseline low-dose CT scans from the Mount Sinai Early Lung and Cardiac Action Program (MS-ELCAP) were reviewed, and it was determined that they can be followed up at the first annual screening rather than having a shorter-term work-up. Purpose: To determine whether the same criteria could be used for solid CP-NCNs newly identified at annual screening examinations. Materials and Methods: With use of the same MS-ELCAP database, all new solid CP-NCNs measuring 30.0 mm or less were identified at 4425 annual screening examinations between 2010 and 2019. In addition, to ensure that no malignant CP-NCNs met the criteria, all solid malignant CP-NCNs of 30.0 mm or less in the International Early Lung Cancer Action Program, or I-ELCAP, database of 111 102 annual screening examinations from the 76 participating institutions between 1992 and 2019 were identified; Mount Sinai is one of these institutions. All identified solid CP-NCNs were reviewed-with the radiologists blinded to diagnosis- for shape (triangular, LOS, polygonal, round, or irregular), margin (smooth or nonsmooth), pleural attachment (broad or narrow), and the presence of emphysema and/or fibrosis within 10.0 mm of each CP-NCN. Intra- and interreader readings were performed, and agreements were determined by using the B-statistic. Results: Of the 76 new solid CP-NCNs, 21 were lung cancers. Benign CP-NCNs were smaller than malignant ones (median diameter, 4.2 mm vs 11 mm; P <.001), had a different shape distributions, more frequently had smooth margins (67% vs 14%; P <.001), and less frequently had emphysema (38% vs 81%; P = .003) or fibrosis (3.6% vs 19%; P = .045) within a 10.0 mm radius. All 22 solid CP-NCNs less than 10.0 mm in average diameter with triangular or LOS shapes and smooth margins were benign, and none of the 21 solid malignant CP-NCNs had these characteristics. Intra- and interobserver agreement for triangular or LOSshaped CP-NCNs with smooth margins was almost perfect (0.77 and 0.69, respectively). Conclusion: The same follow-up recommendation developed for baseline costal pleura-attached noncalcified nodules (CP-NCNs) can be used for CP-NCNs newly identified at annual screening rounds.
UR - http://www.scopus.com/inward/record.url?scp=85120079773&partnerID=8YFLogxK
U2 - 10.1148/radiol.2021210807
DO - 10.1148/radiol.2021210807
M3 - Article
C2 - 34546130
AN - SCOPUS:85120079773
SN - 0033-8419
VL - 301
SP - 724
EP - 731
JO - Radiology
JF - Radiology
IS - 3
ER -