TY - JOUR
T1 - Brightness alters Heidelberg Retinal Flowmeter measurements in an in vitro model
AU - Tsang, Alexander C.
AU - Harris, Alon
AU - Kagemann, Larry
AU - Chung, Hak Sung
AU - Snook, Bryan M.
AU - Garzozi, Hanna J.
PY - 1999
Y1 - 1999
N2 - PURPOSE. The Heidelberg Retinal Flowmeter (HRF), a laser Doppler flowmetry device, has captured interest as a research and clinical tool for measurement of ocular blood flow. Concerns remain about the range and accuracy of the values that it reports. METHODS. An in vitro blood-flow model was constructed to provide well-controlled laminar flow through a glass capillary for assessment by HRF. A change in material behind the glass capillary was used to simulate changing brightness conditions between eyes. RESULTS. Velocities reported by the HRF correlated linearly to true velocities below 8.8 mm/sec. Beyond 8.8 mm/sec, HRF readings fluctuated randomly. True velocity and HRF reported velocities were highly correlated, with r = 0.967 (P < 0.001) from 0.0 mm/sec to 2.7 mm/sec mean velocity using a light background, and r = 0.900 (P < 0.001) from 2.7 mm/sec to 8.8 mm/sec using a darker background. However, a large change in the γ-intercept occurred in the calibration curve with the background change. CONCLUSIONS. The HRF may report velocities inaccurately because of varying brightness in the fundus. In the present experiment, a darker background produced an overreporting of velocities. An offset, possibly introduced by a noise correction routine, apparently contributed to the inaccuracies of the HRF measurements. Such offsets vary with local and global brightness. Therefore, HRF measurements may be error prone when comparing eyes. When used to track perfusion in a single eye over time, meaningful comparison may be possible if meticulous care is taken to align vessels and intensity controls to achieve a similar level of noise correction between measurements.
AB - PURPOSE. The Heidelberg Retinal Flowmeter (HRF), a laser Doppler flowmetry device, has captured interest as a research and clinical tool for measurement of ocular blood flow. Concerns remain about the range and accuracy of the values that it reports. METHODS. An in vitro blood-flow model was constructed to provide well-controlled laminar flow through a glass capillary for assessment by HRF. A change in material behind the glass capillary was used to simulate changing brightness conditions between eyes. RESULTS. Velocities reported by the HRF correlated linearly to true velocities below 8.8 mm/sec. Beyond 8.8 mm/sec, HRF readings fluctuated randomly. True velocity and HRF reported velocities were highly correlated, with r = 0.967 (P < 0.001) from 0.0 mm/sec to 2.7 mm/sec mean velocity using a light background, and r = 0.900 (P < 0.001) from 2.7 mm/sec to 8.8 mm/sec using a darker background. However, a large change in the γ-intercept occurred in the calibration curve with the background change. CONCLUSIONS. The HRF may report velocities inaccurately because of varying brightness in the fundus. In the present experiment, a darker background produced an overreporting of velocities. An offset, possibly introduced by a noise correction routine, apparently contributed to the inaccuracies of the HRF measurements. Such offsets vary with local and global brightness. Therefore, HRF measurements may be error prone when comparing eyes. When used to track perfusion in a single eye over time, meaningful comparison may be possible if meticulous care is taken to align vessels and intensity controls to achieve a similar level of noise correction between measurements.
UR - http://www.scopus.com/inward/record.url?scp=0033024628&partnerID=8YFLogxK
M3 - Article
C2 - 10067987
AN - SCOPUS:0033024628
SN - 0146-0404
VL - 40
SP - 795
EP - 799
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 3
ER -