Abstract
The incorporation of a multicomponent, cofactor-dependant P450 into a microfluidic biochip is demonstrated. The PikC hydroxylase Streptomyces venezuelae was incorporated into a PDMS-based microfluidic channel. The enzyme was immobilized to Ni-NTA agarose beads via in situ attachment following the addition of the beads to the microchannel. The enzyme loading was ∼6 μg per mg of beads resulting in a microchannel loading of 10.7 mg/mL. This high enzyme loading enabled the rapid hydroxylation of the macrolide YC-17 to methymycin and neomethymycin in about equal amounts with a conversion of >90% at a flow rate of 70 nL/min. This high reactivity allowed rapid hydroxylation reactions to be performed with short residence times, which is critical for complex enzymes with limited inherent stability.
| Original language | English |
|---|---|
| Pages (from-to) | 528-535 |
| Number of pages | 8 |
| Journal | Biotechnology and Bioengineering |
| Volume | 88 |
| Issue number | 4 |
| DOIs | |
| State | Published - 20 Nov 2004 |
| Externally published | Yes |
Keywords
- Hydroxylation
- Microfluidics
- P450
- Polyketide
Fingerprint