T1 - Automated measurement of pulmonary artery in low-dose non-contrast chest CT images
AU - Xie, Yiting
AU - Liang, Mingzhu
AU - Yankelevitz, David F.
AU - Henschke, Claudia I.
AU - Reeves, Anthony P.
N1 - Publisher Copyright:
© 2015 SPIE.
PY - 2015
Y1 - 2015
N2 - A new measurement of the pulmonary artery diameter is obtained where the artery may be robustly segmented between the heart and the artery bifurcation. An automated algorithm is presented that can make this pulmonary artery measurement in low-dose non-contrast chest CT images. The algorithm uses a cylinder matching method following geometric constraints obtained from other adjacent organs that have been previously segmented. This new measurement and the related ratio of pulmonary artery to aortic artery measurement are compared to traditional manual approaches for pulmonary artery characterization. The algorithm was qualitatively evaluated on 124 low-dose and 223 standard-dose non-contrast chest CT scans from two public datasets; 324 out of the 347 cases had good segmentations and in the other 23 cases there was significant boundary inaccuracy. For quantitative evaluation, the comparison was to manually marked pulmonary artery boundary in an axial slice in 45 cases; the resulting average Dice Similarity Coefficient was 0.88 (max 0.95, min 0.74). For the 45 cases with manual markings, the correlation between the automated pulmonary artery to ascending aorta diameter ratio and manual ratio at pulmonary artery bifurcation level was 0.81. Using Bland-Altman analysis, the mean difference of the two ratios was 0.03 and the limits of agreement was (-0.12, 0.18). This automated measurement may have utility as an alternative to the conventional manual measurement of pulmonary artery diameter at the bifurcation level especially in the context of noisy low-dose CT images.
AB - A new measurement of the pulmonary artery diameter is obtained where the artery may be robustly segmented between the heart and the artery bifurcation. An automated algorithm is presented that can make this pulmonary artery measurement in low-dose non-contrast chest CT images. The algorithm uses a cylinder matching method following geometric constraints obtained from other adjacent organs that have been previously segmented. This new measurement and the related ratio of pulmonary artery to aortic artery measurement are compared to traditional manual approaches for pulmonary artery characterization. The algorithm was qualitatively evaluated on 124 low-dose and 223 standard-dose non-contrast chest CT scans from two public datasets; 324 out of the 347 cases had good segmentations and in the other 23 cases there was significant boundary inaccuracy. For quantitative evaluation, the comparison was to manually marked pulmonary artery boundary in an axial slice in 45 cases; the resulting average Dice Similarity Coefficient was 0.88 (max 0.95, min 0.74). For the 45 cases with manual markings, the correlation between the automated pulmonary artery to ascending aorta diameter ratio and manual ratio at pulmonary artery bifurcation level was 0.81. Using Bland-Altman analysis, the mean difference of the two ratios was 0.03 and the limits of agreement was (-0.12, 0.18). This automated measurement may have utility as an alternative to the conventional manual measurement of pulmonary artery diameter at the bifurcation level especially in the context of noisy low-dose CT images.
KW - Ascending aorta measurement
KW - Computer-based segmentation
KW - Low-dose CT
KW - Pulmonary artery
KW - Pulmonary artery trunk measurement
UR - https://www.scopus.com/pages/publications/84948845202
U2 - 10.1117/12.2081992
DO - 10.1117/12.2081992
M3 - Conference contribution
AN - SCOPUS:84948845202
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2015
A2 - Hadjiiski, Lubomir M.
A2 - Tourassi, Georgia D.
PB - SPIE
T2 - SPIE Medical Imaging Symposium 2015: Computer-Aided Diagnosis
Y2 - 22 February 2015 through 25 February 2015
ER -