Skip to main navigation Skip to search Skip to main content

Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation

  • Yunfen Wu
  • , Douglas Cohen
  • , Maria J. Tellez
  • , George V. DiGiacinto
  • , Alfonso Vázquez Barquero
  • , Sedat Ulkatan

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

The main aim of this study was evaluating the reliability of stimulus-evoked electromyography (using different thresholds for stimulation of the instrumentation devices) for minimally invasive pedicle screw placement in the lumbosacral spine. A threshold of 5 mA was applied for the pedicle access needle. 7 mA was applied for the tapscrew and pedicle screw stimulation. The existence of threshold differences between vertebral levels was also assessed. All patients underwent postoperative computed tomography (CT) to determine the accuracy of pedicle screw placement. A total of 172 percutaneous pedicle screws were placed in 52 patients. 94.1% of screws were placed at L4, L5 and S1 vertebral levels. No statistically significant differences existed in thresholds of the pedicle access needles, tapscrews and pedicle screws between vertebral levels. In four instances, the pedicle access needle stimulation had a threshold of 5 mA (no breaches were associated). In the rest of occasions, the pedicle access needles had stimulation thresholds above 5 mA. In all instances, tapscrew and pedicle screw thresholds were above 7 mA; the tapscrews and pedicle screws had significantly greater thresholds than the pedicle access needles. No statistically significant differences existed in thresholds between tapscrews and pedicle screws. Postoperative CT imaging revealed one lateral pedicle violation. Both breach rate and false negative rate were 0.5%. No false positive cases were observed. No patients experienced postoperative pedicle screw–related neurologic deficits. A threshold of 5 mA for the pedicle access needle stimulation seems to be safe. Greater than 7 mA should be used for the tapscrew and pedicle screw stimulation.

Original languageEnglish
Pages (from-to)224-228
Number of pages5
JournalJournal of Clinical Neuroscience
Volume72
DOIs
StatePublished - Feb 2020
Externally publishedYes

Keywords

  • EMG
  • Lumbosacral spine fixation
  • Minimally invasive
  • Pedicle access needle
  • Pedicle screw
  • Tapscrew
  • Threshold

Fingerprint

Dive into the research topics of 'Application of different thresholds for instrumentation device testing in minimally invasive lumbosacral spine fixation'. Together they form a unique fingerprint.

Cite this