Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: Role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation

  • Craig E. Hjemdahl-Monsen
  • , John A. Ambrose
  • , Susan Borrico
  • , Marc Cohen
  • , Warren Sherman
  • , Dimitrios Alexopoulos
  • , Richard Gorlin
  • , Valentin Fuster

Research output: Contribution to journalArticlepeer-review

47 Scopus citations

Abstract

There are few in vivo data concerning the mechanisms of balloon inflation during coronary angioplasty. To characterize how lesions dilate, videodensitometry was used to measure the diameter of the inflated balloon across 29 coronary lesions in 27 patients. Pressure-diameter curves for each lesion were derived with use of a standardized incremental inflation protocol in which pressures between 2 and 6 atm in 3 mm low profile balloons approximated normal vessel diameter. The diameter of coronary stenosis before and after angioplasty was also measured. Pressure-diameter curves showed that the most improvement in luminal caliber occurred at low inflation pressure. A distensibility factor was defined as the ratio of the amount of balloon inflation at 2 atm compared with the balloon diameter at 6 atm. Eccentric irregular lesions (n = 11) had a greater distensibility factor (0.49 ± 0.17) than did lesions (n = 18) without this configuration (0.33 ± 0.14) (p < 0.02). The former were soft, presumably because of thrombus in these lesions. In addition, there were no differences in patterns of balloon inflation for lesions requiring additional inflation or for dilations resulting in an intimal crack or dissection after angioplasty. There was often a loss of iuminal caliber when balloon diameter at 6 atm was compared with the diameter after angroplasty. This was defined as elasticity or recoil. There was a significant direct correlation between the amount of elasticity and the extent of balloon Inflation at 6 atm (that is, lesions more fully dilated at 6 atm showed more elasticity). This relation was most striking for eccentric irregular lesions (r = 0.80, p < 0.001) and was unchanged by administration of nitroglycerin. Thus, pressure-diameter curves analysing distensibility and elasticity provide information about mechanisms of coronary angioplasty that probably reflect lesion composition and geometry. This approach may have clinical relevance.

Original languageEnglish
Pages (from-to)569-575
Number of pages7
JournalJournal of the American College of Cardiology
Volume16
Issue number3
DOIs
StatePublished - Sep 1990

Fingerprint

Dive into the research topics of 'Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: Role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation'. Together they form a unique fingerprint.

Cite this