An Observational Crossover Study of People Using Real-Time Continuous Glucose Monitors Versus Self-Monitoring of Blood Glucose: Real-World Evidence Using Electronic Medical Record Data From More Than 12,000 People With Type 1 Diabetes

Nudrat Noor, Gregory Norman, Rona Sonabend, Lily Chao, Manmohan Kamboj, Lauren Golden, M. Tracy Bekx, Susan Hseih, Carol Levy, Janine Sanchez, Robert Rapaport, Osagie Ebekozien

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: We used real-world electronic health record (EHR) data to examine HbA1c levels among children and adults with type 1 diabetes (T1D) who are classified as continuous glucose monitor (CGM) users after T1D diagnosis and switch to self-monitoring of blood glucose (SMBG) during follow-up, versus people who opt for SMBG after T1D diagnosis and switch to CGM during follow-up visits. Methods: We conducted an observational, case-crossover study using electronic medical record (EMR) data from the T1D Exchange Quality Improvement Collaborative. The primary outcome in this study was HbA1c. Baseline HbA1c levels were taken at the index date, corresponding to initial device classification, and compared with HbA1c value recorded at the clinic visit following device switch. Results: Of all patients classified in the SMBG group, 7,706 switched to CGM use within the 5-year study time frame, and 5,123 of all initial CGM users switched to SMBG within the study time frame and were included in this analysis. At baseline, median (interquartile range [IQR]) HbA1c for SMBG use was 8.1 (2.4), whereas postcrossover to CGM use, there was a decline in median (IQR) levels to 7.7 (1.9) (P <.001). For baseline CGM users, median (IQR) HbA1c levels were 7.9 (2.0), and postcrossover to SMBG, median (IQR) HbA1c levels increased to 8.0 (2.9) (P <.001). Conclusion: We found that people who switched to CGM use had significantly improved HbA1c levels compared to those who switched to glucose monitoring with SMBG.

Original languageEnglish
Pages (from-to)63-71
Number of pages9
JournalJournal of diabetes science and technology
Volume19
Issue number1
DOIs
StatePublished - Jan 2025

Keywords

  • CGM
  • HbA1c
  • SMBG
  • T1D
  • crossover study

Fingerprint

Dive into the research topics of 'An Observational Crossover Study of People Using Real-Time Continuous Glucose Monitors Versus Self-Monitoring of Blood Glucose: Real-World Evidence Using Electronic Medical Record Data From More Than 12,000 People With Type 1 Diabetes'. Together they form a unique fingerprint.

Cite this