An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings

Katherine Longardner, Qian Shen, Bin Tang, Brenton A. Wright, Prantik Kundu, Fatta B. Nahab

Research output: Contribution to journalArticlepeer-review

Abstract

Introduction: Essential tremor is a common movement disorder. Numerous validated clinical rating scales exist to quantify essential tremor severity by employing raterdependent visual observation but have limitations, including the need for trained human raters and the lack of precision and sensitivity compared to technology-based objective measures. Other continuous objective methods to quantify tremor amplitude have been developed, but frequently provide unitless measures (e.g., tremor power), limiting real-world interpretability. We propose a novel algorithm to measure kinetic tremor amplitude using digital spiral drawings, applying the V3 framework (sensor verification, analytical validation, and clinical validation) to establish reliability and clinical utility. Methods: Archimedes spiral drawings were recorded on a digitizing tablet from participants (n = 7) enrolled in a randomized placebo control double-blinded crossover pilot trial evaluating the efficacy of oral cannabinoids in reducing essential tremor. We developed an algorithm to calculate the mean and maximum tremor amplitude derived from the spiral tracings. We compared the digitally measured tremor amplitudes to manual measurement to evaluate sensor reliability, determined the test-retest reliability of the digital output across two short-interval repeated measures, and compared the digital measure to kinetic tremor severity graded using The Essential Tremor Rating Assessment Scale (TETRAS) score for spiral drawings. Results: This algorithm for automated assessment of kinetic tremor amplitude from digital spiral tracings demonstrated a high correlation with manual spot measures of tremor amplitude, excellent test-retest reliability, and a high correlation with human ratings of the TETRAS score for spiral drawing severity when the tremor severity was rated "slight tremor"or worse. Discussion: This digital measure provides a simple and clinically relevant evaluation of kinetic tremor amplitude that shows promise as a potential future endpoint for use in clinical trials of essential tremor.

Original languageEnglish
Pages (from-to)140-148
Number of pages9
JournalDigital Biomarkers
Volume8
Issue number1
DOIs
StatePublished - 20 Jul 2024

Keywords

  • Algorithms
  • Digital biomarker
  • Digital health technology
  • Digital outcome measure
  • Objective data
  • Objective endpoint
  • Spiral drawing
  • Tremor

Fingerprint

Dive into the research topics of 'An Algorithm for Automated Measurement of Kinetic Tremor Magnitude Using Digital Spiral Drawings'. Together they form a unique fingerprint.

Cite this