TY - JOUR
T1 - Acoustic rhinometry predicts tolerance of nasal continuous positive airway pressure
T2 - A pilot study
AU - Morris, Luc G.
AU - Setlur, Jennifer
AU - Burschtin, Omar E.
AU - Steward, David L.
AU - Jacobs, Joseph B.
AU - Lee, Kelvin C.
N1 - Funding Information:
This article is part of an Ashton-Stravinsky research project which was led by Stephanie Jordan and also involved making the video/DVD Ashton to Stravinsky: A Study of Four Ballets. It was generously funded by the Arts and Humanities Research Council (AHRC).
PY - 2006/3
Y1 - 2006/3
N2 - Background: Nasal continuous positive airway pressure (nCPAP) is usually the first-line intervention for obstructive sleep apnea, but up to 50% of patients are unable to tolerate therapy because of discomfort - usually nasal complaints. No factors have been definitively correlated with nCPAP tolerance, although nasal cross-sectional area has been correlated with the level of CPAP pressure, and nasal surgery improves nCPAP compliance. This study examined the relationship between nasal cross-sectional area and nCPAP tolerance. Methods: We performed acoustic rhinometry on 34 obstructive sleep apnea patients at the time of the initial sleep study. Patients titrated to nCPAP were interviewed 18 months after starting therapy to determine CPAP tolerance. Demographic, polysomnographic, and nasal cross-sectional area data were compared between CPAP-tolerant and -intolerant patients. Results: Between 13 tolerant and 12 intolerant patients, there were no significant differences in age, gender, body mass index, CPAP level, respiratory disturbance index, or subjective nasal obstruction. Cross-sectional area at the inferior turbinate differed significantly between the two groups (p = 0.03). This remained significant after multivariate analysis for possibly confounding variables. A cross-sectional area cutoff of 0.6 cm2 at the head of the inferior turbinate carried a sensitivity of 75% and specificity of 77% for CPAP intolerance in this patient group. Conclusion: Nasal airway obstruction correlated with CPAP tolerance, supporting an important role for the nose in CPAP, and providing a physiological basis for improved CPAP compliance after nasal surgery. Objective nasal evaluation, but not the subjective report of nasal obstruction, may be helpful in the management of these patients.
AB - Background: Nasal continuous positive airway pressure (nCPAP) is usually the first-line intervention for obstructive sleep apnea, but up to 50% of patients are unable to tolerate therapy because of discomfort - usually nasal complaints. No factors have been definitively correlated with nCPAP tolerance, although nasal cross-sectional area has been correlated with the level of CPAP pressure, and nasal surgery improves nCPAP compliance. This study examined the relationship between nasal cross-sectional area and nCPAP tolerance. Methods: We performed acoustic rhinometry on 34 obstructive sleep apnea patients at the time of the initial sleep study. Patients titrated to nCPAP were interviewed 18 months after starting therapy to determine CPAP tolerance. Demographic, polysomnographic, and nasal cross-sectional area data were compared between CPAP-tolerant and -intolerant patients. Results: Between 13 tolerant and 12 intolerant patients, there were no significant differences in age, gender, body mass index, CPAP level, respiratory disturbance index, or subjective nasal obstruction. Cross-sectional area at the inferior turbinate differed significantly between the two groups (p = 0.03). This remained significant after multivariate analysis for possibly confounding variables. A cross-sectional area cutoff of 0.6 cm2 at the head of the inferior turbinate carried a sensitivity of 75% and specificity of 77% for CPAP intolerance in this patient group. Conclusion: Nasal airway obstruction correlated with CPAP tolerance, supporting an important role for the nose in CPAP, and providing a physiological basis for improved CPAP compliance after nasal surgery. Objective nasal evaluation, but not the subjective report of nasal obstruction, may be helpful in the management of these patients.
UR - https://www.scopus.com/pages/publications/33646262895
U2 - 10.1080/01472520600744977
DO - 10.1080/01472520600744977
M3 - Article
C2 - 16686374
AN - SCOPUS:33646262895
SN - 1050-6586
VL - 20
SP - 133
EP - 137
JO - American Journal of Rhinology
JF - American Journal of Rhinology
IS - 2
ER -