TY - JOUR
T1 - A unified strategy to focal brachytherapy incorporating transperineal biopsy, image fusion, and real-time implantation with and without rectal spacer simulated in prostate phantoms
AU - Vanneste, Ben G.L.
AU - Skouteris, Basile
AU - Pinheiro, Luis Campos
AU - Voncken, Robert
AU - Van Limbergen, Evert J.
AU - Lutgens, Ludy
AU - Fonteyne, Valérie
AU - Van Praet, Charles
AU - Lumen, Nicolaas
AU - Sheu, Rendi
AU - Stock, Richard
AU - Stone, Nelson N.
N1 - Publisher Copyright:
© 2024 Termedia Publishing House Ltd.. All rights reserved.
PY - 2024
Y1 - 2024
N2 - Purpose: To develop an approach to the diagnosis and treatment of prostate cancer using one platform for fusion biopsy, followed by focal gland ablation utilizing permanent prostate brachytherapy with and without a rectal spacer. Material and methods: Prostate phantoms containing multiparametric magnetic resonance imaging (mpMRI) regions of interest (ROI) underwent fusion biopsy, followed by image co-registration of positive sites to a treatment planning brachytherapy program. A partial hemi-ablation and both posterior lobes using a Mick applicator and linked stranded seeds were simulated. Dummy sources were modeled as iodine-125 (125I) with a prescribed dose of at least 210 Gy to gross tumor (GTV) and clinical target volume (CTV), as defined by mpMRI visible ROI and surrounding negative biopsy sites. Computer tomograms (CT) were performed post-implant prior to and after rectal spacer insertion. Different prostate and rectal constraints were compared with and without the spacer. Results: The intra-operative focal volumes of CTV ranged from 6.2 to 14.9 cc (mean, 11.3 cc), and the ratio of focal volume/whole prostate volume ranged between 0.19 and 0.42 (mean, 0.31). The intra- and post-operative mean focal D90 of GTV, CTV, and for the entire prostate gland was 265 Gy and 235 Gy, 214 Gy and 213 Gy, and 66.1 Gy and 57 Gy, respectively. On average, 13 mm separation was achieved between the prostate and the rectum (range, 12-14 mm) on post-operative CT. The mean doses in Gy to 2 cc of the rectum (D2cc) without spacer vs. with spacer were 39.8 Gy vs. 32.6 Gy, respectively. Conclusions: Doses above 200 Gy and the implantation of seeds in clinically significant region for focal therapy in phantoms are feasible. All rectal dosimetric parameters improved for the spacer implants, as compared with the nonspacer implants. Further validation of this concept is warranted in clinical trials.
AB - Purpose: To develop an approach to the diagnosis and treatment of prostate cancer using one platform for fusion biopsy, followed by focal gland ablation utilizing permanent prostate brachytherapy with and without a rectal spacer. Material and methods: Prostate phantoms containing multiparametric magnetic resonance imaging (mpMRI) regions of interest (ROI) underwent fusion biopsy, followed by image co-registration of positive sites to a treatment planning brachytherapy program. A partial hemi-ablation and both posterior lobes using a Mick applicator and linked stranded seeds were simulated. Dummy sources were modeled as iodine-125 (125I) with a prescribed dose of at least 210 Gy to gross tumor (GTV) and clinical target volume (CTV), as defined by mpMRI visible ROI and surrounding negative biopsy sites. Computer tomograms (CT) were performed post-implant prior to and after rectal spacer insertion. Different prostate and rectal constraints were compared with and without the spacer. Results: The intra-operative focal volumes of CTV ranged from 6.2 to 14.9 cc (mean, 11.3 cc), and the ratio of focal volume/whole prostate volume ranged between 0.19 and 0.42 (mean, 0.31). The intra- and post-operative mean focal D90 of GTV, CTV, and for the entire prostate gland was 265 Gy and 235 Gy, 214 Gy and 213 Gy, and 66.1 Gy and 57 Gy, respectively. On average, 13 mm separation was achieved between the prostate and the rectum (range, 12-14 mm) on post-operative CT. The mean doses in Gy to 2 cc of the rectum (D2cc) without spacer vs. with spacer were 39.8 Gy vs. 32.6 Gy, respectively. Conclusions: Doses above 200 Gy and the implantation of seeds in clinically significant region for focal therapy in phantoms are feasible. All rectal dosimetric parameters improved for the spacer implants, as compared with the nonspacer implants. Further validation of this concept is warranted in clinical trials.
KW - brachytherapy
KW - focal
KW - image fusion
KW - prostate cancer
KW - rectum spacer
KW - toxicity reduction
KW - transperineal biopsy
UR - http://www.scopus.com/inward/record.url?scp=85195077289&partnerID=8YFLogxK
U2 - 10.5114/jcb.2024.139280
DO - 10.5114/jcb.2024.139280
M3 - Article
AN - SCOPUS:85195077289
SN - 1689-832X
VL - 16
SP - 139
EP - 149
JO - Journal of Contemporary Brachytherapy
JF - Journal of Contemporary Brachytherapy
IS - 2
ER -