Skip to main navigation Skip to search Skip to main content

A tablet-interfaced high-resolution microendoscope with automated image interpretation for real-time evaluation of esophageal squamous cell neoplasia

  • Timothy Quang
  • , Richard A. Schwarz
  • , Sanford M. Dawsey
  • , Mimi C. Tan
  • , Kalpesh Patel
  • , Xinying Yu
  • , Guiqi Wang
  • , Fan Zhang
  • , Hong Xu
  • , Sharmila Anandasabapathy
  • , Rebecca Richards-Kortum

Research output: Contribution to journalArticlepeer-review

73 Scopus citations

Abstract

Background and Aims In recent years high-resolution microendoscopy (HRME) has shown potential to improve screening for esophageal squamous cell neoplasia. Furthering its utility in a clinical setting, especially in lower-resource settings, could be accomplished by reducing the size and cost of the system as well as incorporating the ability of real-time, objective feedback. This article describes a tablet-interfaced HRME with fully automated, real-time image analysis. Methods The performance of the tablet-interfaced HRME was assessed by acquiring images from the oral mucosa in a normal volunteer. An automated, real-time analysis algorithm was developed and evaluated using training, test, and validation images from a previous in vivo study of 177 patients referred for screening or surveillance endoscopy in China. The algorithm was then implemented in a tablet HRME that was used to obtain and analyze images from esophageal tissue in 3 patients. Images were displayed alongside the probability that the imaged region was neoplastic. Results The tablet-interfaced HRME demonstrated comparable imaging performance at a lower cost compared with first-generation laptop-interfaced HRME systems. In a post-hoc quantitative analysis, the algorithm identified neoplasia with a sensitivity and specificity of 95% and 91%, respectively, in the validation set compared with 84% and 95% achieved in the original study. Conclusions The tablet-based HRME is a low-cost tool that provides quantitative diagnostic information to the endoscopist in real time. This could be especially beneficial in lower-resource settings for operators with less experience interpreting HRME images.

Original languageEnglish
Pages (from-to)834-841
Number of pages8
JournalGastrointestinal Endoscopy
Volume84
Issue number5
DOIs
StatePublished - 1 Nov 2016
Externally publishedYes

Fingerprint

Dive into the research topics of 'A tablet-interfaced high-resolution microendoscope with automated image interpretation for real-time evaluation of esophageal squamous cell neoplasia'. Together they form a unique fingerprint.

Cite this