Abstract
The authors present a technique of transscleral fixation of a posterior chamber intraocular lens modified to permit a small-incision approach by using a foldable silicone lens. This modification improved intraoperative globe stability and reduced operative time. This procedure also has the potential for expediting postoperative recovery and visual rehabilitation.
Original language | English |
---|---|
Pages (from-to) | 473-475 |
Number of pages | 3 |
Journal | Ophthalmic Surgery and Lasers |
Volume | 27 |
Issue number | 6 |
State | Published - Jun 1996 |