TY - JOUR
T1 - A new noninvasive technique for imaging atherosclerotic plaque in the aortic arch of stroke patients by transcutaneous real-time B-mode ultrasonography
T2 - An initial report
AU - Weinberger, Jesse
AU - Azhar, Salman
AU - Danisi, Fabio
AU - Hayes, Richard
AU - Goldman, Martin
PY - 1998/3
Y1 - 1998/3
N2 - Background and Purpose - Aortic arch atherosclerotic plaque is a probable source of atheroembolic stroke. Transesophageal echocardiography (TEE) has been used to image the aorta of patients with stroke to identify atherosclerotic plaque. TEE is moderately invasive and does not always visualize plaques present in the distal ascending aorta and proximal aortic arch. Methods - In the current study, transcutaneous B-mode ultrasonography was performed to image the aortic arch through a lateral supraclavicular window, and the results were compared with those of TEE in 20 patients. The aorta was subdivided into the proximal ascending (PAsc), distal ascending (DAsc), proximal aortic arch (PAA), and distal aortic arch (DAA) to be certain the plaques identified by each technique were the same. Plaques were characterized as simple (<:4 mm thick) or complex (>4 mm thick). Results - In the PAsc, 8 simple plaques were identified with TEE but not with B-mode. In the DAsc, 1 complex plaque was identified with both techniques, and B-mode identified 1 additional complex and 1 simple plaque. In the PAA, 6 simple and 5 complex plaques were identified by both techniques, and TEE identified 1 additional complex plaque. In the DAA, TEE identified 2 simple and 2 complex plaques; B-mode identified 3 complex plaques. Conclusions - B-mode imaging compared favorably with TEE in identification of plaques in the aortic arch and distal ascending aorta, although it could not identify simple plaques in the proximal ascending. B-mode could visualize plaques not seen by TEE in the distal ascending aorta. B-mode ultrasonography is complementary to TEE in performance of a comprehensive assessment of plaque in the aortic arch and provides a noninvasive method for sequential studies of plaques that can be visualized.
AB - Background and Purpose - Aortic arch atherosclerotic plaque is a probable source of atheroembolic stroke. Transesophageal echocardiography (TEE) has been used to image the aorta of patients with stroke to identify atherosclerotic plaque. TEE is moderately invasive and does not always visualize plaques present in the distal ascending aorta and proximal aortic arch. Methods - In the current study, transcutaneous B-mode ultrasonography was performed to image the aortic arch through a lateral supraclavicular window, and the results were compared with those of TEE in 20 patients. The aorta was subdivided into the proximal ascending (PAsc), distal ascending (DAsc), proximal aortic arch (PAA), and distal aortic arch (DAA) to be certain the plaques identified by each technique were the same. Plaques were characterized as simple (<:4 mm thick) or complex (>4 mm thick). Results - In the PAsc, 8 simple plaques were identified with TEE but not with B-mode. In the DAsc, 1 complex plaque was identified with both techniques, and B-mode identified 1 additional complex and 1 simple plaque. In the PAA, 6 simple and 5 complex plaques were identified by both techniques, and TEE identified 1 additional complex plaque. In the DAA, TEE identified 2 simple and 2 complex plaques; B-mode identified 3 complex plaques. Conclusions - B-mode imaging compared favorably with TEE in identification of plaques in the aortic arch and distal ascending aorta, although it could not identify simple plaques in the proximal ascending. B-mode could visualize plaques not seen by TEE in the distal ascending aorta. B-mode ultrasonography is complementary to TEE in performance of a comprehensive assessment of plaque in the aortic arch and provides a noninvasive method for sequential studies of plaques that can be visualized.
KW - Aortic arch
KW - Atherosclerosis
KW - Echocardiography
KW - Transesophageal
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=0031894262&partnerID=8YFLogxK
U2 - 10.1161/01.STR.29.3.673
DO - 10.1161/01.STR.29.3.673
M3 - Article
C2 - 9506611
AN - SCOPUS:0031894262
SN - 0039-2499
VL - 29
SP - 673
EP - 676
JO - Stroke
JF - Stroke
IS - 3
ER -