Skip to main navigation Skip to search Skip to main content

A comparison of motility: Autogenous dermis-fat vs synthetic spherical implants

  • S. L. Bosniak
  • , F. Nesi
  • , B. C. Smith
  • , B. Schechter
  • , R. Cote

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

The socket and prosthesis motility and the forniceal depths in a group of 47 patients who had undergone enucleation and implantation of synthetic spherical implants were compared with those in a group of 34 patients who had undergone enucleation and implantation of autogenous dermis-fat orbital implants. The primarty autogenous dermisfat orbital implants provided greater socket movement and deeper fornices than the synthetic spherical implants. Prosthesis motility, however, was the ame in the two groups.

Original languageEnglish
Pages (from-to)889-891
Number of pages3
JournalOphthalmic Surgery
Volume20
Issue number12
StatePublished - 1989