Skip to main navigation Skip to search Skip to main content

A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma

  • Lale Kostakoglu
  • , Uǧur Uysal
  • , Enis Özyar
  • , Figen B. Demirkazik
  • , Mutlu Hayran
  • , Lale Atahan
  • , Coçkun F. Bekdik

Research output: Contribution to journal › Article › peer-review

33 Scopus citations

Abstract

The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n = 22) or following therapy (n = 16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statisti cal difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true positive in all patients (n = 7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤ 1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.

Original languageEnglish
Pages (from-to)621-628
Number of pages8
JournalEuropean Journal of Nuclear Medicine
Volume24
Issue number6
DOIs
StatePublished - 1997
Externally publishedYes

Keywords

  • Nasopharyngeal carcinoma
  • Residual/recurrent disease
  • Technetium tetrofosmin
  • Technetium-99m sestamibi

Fingerprint

Dive into the research topics of 'A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma'. Together they form a unique fingerprint.

Cite this