3D Xplane Echocardiographic Technique for Validation of Mitral Leaflet Separation to Assess Severity of Mitral Stenosis

Rajendra K. Gokhroo, Bhanwar L. Ranwa, Kamal Kishor, Kumari Priti, Ananthraj Avinash, Sajal Gupta, Devendra Bisht

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Background: Determining the severity of mitral stenosis (MS) is important for both prognostic and therapeutic implications. Mitral valve area (MVA) calculation techniques have more limitations. Mitral leaflet separation (MLS) is a precise and operator friendly alternative to planimetry. In contrast to previous researchers, we have used a novel 3D Xplane technique to validate MLS for assessing the severity of MS. 3D Xplane is superior for validation of MLS due to simultaneous real time acquisition of MLS in parasternal long-axis view and corresponding MVA by planimetry in parsternal short-axis view. Methods: It was a prospective observational single center study. A total of 174 patients with MS were evaluated for MVA estimation by various echocardiographic modalities. Maximum leaflet separation and corresponding planimetered MVA were measured using novel 3D Xplane technique. Results: With 3D Xplane technique, there was strong positive correlation between planimetered MVA and MLS (R = 0.925, P < 0.001), irrespective of coexisting MR (R = 0.886, P < 0.001) or AF (R = 0.912, P < 0.001). Receiver operating characteristic curves of MLS demonstrated AUC for mild and severe MS to be 0.966 and 0.995, respectively. MLS less than 8.62 mm predicted severe MS with 95.5% sensitivity and 94.7% specificity and MLS more than 12.23 mm predicted mild MS with 93.2% sensitivity and 91.4% specificity. Conclusion: In our study, a strong correlation between planimetered MVA and MLS was found using 3D Xplane technique. 3D Xplane thus validates and standardizes MLS by excluding errors due to temporal and spatial variations which are important limitations of 2D echocardiography.

Original languageEnglish
Pages (from-to)896-901
Number of pages6
JournalEchocardiography
Volume33
Issue number6
DOIs
StatePublished - 1 Jun 2016
Externally publishedYes

Keywords

  • 3D Xplane echocardiography
  • correlation
  • mitral leaflet separation
  • mitral valve area
  • planimetry
  • validation

Fingerprint

Dive into the research topics of '3D Xplane Echocardiographic Technique for Validation of Mitral Leaflet Separation to Assess Severity of Mitral Stenosis'. Together they form a unique fingerprint.

Cite this